Laser
Gemini South Laser
GS Laser History:The Gemini South (GS) Observatory acquired a 50W sodium Guide Star Laser System back in March 2010, as one of the key component of the Gemini Multi-Conjugate Adaptive Optics System (GeMS) project. After a successful post-delivery acceptance in the laboratory, the system was installed on the elevation platform of the telescope.
March 2010: The Gemini South Telescope recieves its new 50W sodium laser
Following an intensive period of optimization, the Gemini South Laser Guide Star Facility (LGSF) delivered its first light on the sky in January 2011. Over the few months following the event, and while the LGSF was being commissioned, the GS laser team was able to gather a lot of data concerning its laser system, and therefore ways to work on improving both its overall performance and reliability.
GS Laser Design:
The system architecture is based on single pass Sum Frequency Mixing (SFM) of high power outputs of two Nd:YAG MOPAs (master oscillator-power amplifier) operating at 1064 nm and 1319 nm.
GS Laser performance:Gemini South’s (GS) 1319nm & 1064nm MOPAs nominally produce average powers of 75 W and 110 W, respectively, with 250-300 pico second pulse widths. Table 1: MOPAs performance
The table below contains the system requirements and demonstrated results. The system displays good day to day repeatability after extended 10 hour warm-up periods. However, it does require monthly alignment maintenance to compensate for beam pointing walk off. The mostly likely cause is thermal hysteresis of MO’s opto-mechanical mounts.
|